Commissioning with CANopen
4.2 Commissioning
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
83
4.2.8 Loading the project to the drive unit
Introduction
To load the project to the drive unit, proceed as follows:
Steps
1. Click Connect to target system. An ONLINE connection is established and an
ONLINE/OFFLINE comparison takes place. If any discrepancies are identified, they are
displayed (see screenshot below).
Figure 4-7 ONLINE/OFFLINE comparison (example)
2. You changed the data OFFLINE and now have to load it to the target system. Carry out
the following:
<== Download to target device in the "ONLINE/OFFLINE comparison" dialog box
When the system asks "Are you sure?", click Yes. The system now starts loading the
data.
When the system informs you that the data was successfully loaded to the target
system, click OK.
Click OK for "Load from RAM to ROM".