EasyManua.ls Logo

Siemens SINAMICS S110 - ADD (Adder); SUB (Subtracter); MUL (Multiplier)

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive functions
7.3 Function modules
Function Manual
304 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
7.3.8.7 ADD (adder)
Brief description
REAL-type adder with four inputs
Mode of operation
This function block adds (in accordance with the sign) the values entered at inputs X
0
to X
3
.
The result is limited to a range of -3.4E38 to +3.4E38 and output at output Y.
Y = X
0
+ X
1
+ X
2
+X
3
7.3.8.8 SUB (subtracter)
Brief description
REAL-type subtracter with two inputs
Mode of operation
This function block subtracts (in accordance with the sign) the value entered at input X
1
from
the value entered at input X
0
.
The result is limited to a range of -3.4E38 to +3.4E38 and output at output Y.
Y = X
0
– X
1
7.3.8.9 MUL (multiplier)
Brief description
REAL-type multiplier with four inputs
Mode of operation
This function block multiplies (in accordance with the sign) the values entered at inputs X
0
to
X
3
.
The result is limited to a range of -3.4E38 to +3.4E38 and output at output Y.
Y = X
0
· X
1
· X
2
· X
3

Table of Contents