Drive functions
7.3 Function modules
Function Manual
208 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
7.3.2.3 Integration
The technology controller function is integrated in the system as follows.
Function diagrams (see SINAMICS S110 List Manual)
7950 Fixed values (r0108.16 = 1)
7954 Motorized potentiometer (r0108.16 = 1)
7958 Closed-loop control (r0108.16 = 1)
Overview of important parameters (see SINAMICS S110 List Manual)
Fixed setpoints
p2201[0...n] CO: Technology controller, fixed value 1
...
p2215[0...n] CO: Technology controller, fixed value 15
p2220[0...n] BI: Technology controller fixed value selection bit 0
p2221[0...n] BI: Technology controller fixed value selection bit 1
p2222[0...n] BI: Technology controller fixed value selection bit 2
p2223[0...n] BI: Technology controller fixed value selection bit 3
Motorized potentiometer
p2230[0...n] Technology controller motorized potentiometer configuration
p2235[0...n] BI: Technology controller motorized potentiometer, raise setpoint
p2236[0...n] BI: Technology controller motorized potentiometer, lower setpoint
p2237[0...n] Technology controller motorized potentiometer, maximum value
p2238[0...n] Technology controller motorized potentiometer, minimum value
p2240[0...n] Technology controller motorized potentiometer, start value
r2245 CO: Technology controller motorized potentiometer, setpoint before RFG
p2247[0...n] Technology controller motorized potentiometer, ramp-up time
p2248[0...n] Technology controller motorized potentiometer, ramp-down time
r2250 CO: Technology controller motorized potentiometer, setpoint after RFG