EasyManua.ls Logo

Siemens SINAMICS S110 - Data Sets; CDS: Command Data Set

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic information about the drive system
10.2 Data sets
Function Manual
658 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
10.2 Data sets
10.2.1 CDS: Command Data Set
CDS: Command Data Set
The BICO parameters (binector and connector inputs) are grouped together in a command
data set. These parameters are used to interconnect the signal sources of a drive.
By parameterizing several command data sets and switching between them, the drive can
be operated with different pre-configured signal sources.
A command data set contains the following (examples):
Binector inputs for control commands (digital signals)
ON/OFF, enable signals (p0844, etc.)
Jog (p1055, etc.)
Connector inputs for setpoints (analog signals)
CI: Speed controller speed setpoint 1 (p1155)
Torque limits and scaling factors (p1522, p1523, p1528, p1529)
SINAMICS S110 can manage 2 command data sets.
The following parameters are available for selecting command data sets and for displaying
the currently selected command data set:
The binector input p0810 is used to select a command data set.
p0810 BI: Command data set selection CDS bit 0
If a command data set that does not exist is selected, the current data set remains active.
The selected data set is displayed using parameter (r0836).

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals