EasyManua.ls Logo

Siemens SINAMICS S110 - Transferring PZD

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication
9.5 Communication using USS
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
641
9.5.2 Transferring PZD
Prerequisite
The communications interface must be set to USS protocol.
Defining the process data to be transferred
To define the process data (PZD) to be transferred, proceed as follows:
1. Select <drive> → Communication in STARTER.
Figure 9-47 USS: Defining the PZD receive direction
2. Define the process data (PZD) you want to receive on the Receive direction tab.
3. Define the process data (PZD) you want to send on the Send direction tab.