Basic information about the drive system
10.2 Data sets
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
663
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
p0130 Motor data sets (MDS) number
p0139 Copy motor data set (MDS)
p0140 Encoder data sets (EDS) number
p0180 Drive data sets (DDS) number
p0186 Motor data set (MDS) number
p0187 Encoder 1 encoder data set number
p0188 Encoder 2 encoder data set number
p0809 Copy command data set (CDS)
p0810 BI: Command data set selection CDS bit 0
p0819[0...2] Copy drive data set DDS
p0820 BI: Drive data set selection DDS, bit 0
10.2.6 Using data sets
Copying a command data set
Set parameter p0809 as follows:
1. p0809[0] = number of the command data set to be copied (source)
2. p0809[1] = number of the command data to which the data is to be copied (target)
3. p0809[2] = 1
Start copying.
Copying is finished when p0809[2] = 0.
Note
In STARTER, you can copy the command data sets (Drive → Configuration → "Command
data sets" tab).
You can select the displayed command data set in the relevant STARTER screens.
Copying a drive data set
Set parameter p0819 as follows:
1. p0819[0] = Number of the drive data set to be copied (source)
2. p0819[1] = Number of the drive data set to which the data is to be copied (target)
3. p0819[2] = 1