EasyManua.ls Logo

Siemens SINAMICS S110 - Runtime (Operating Hours Counter)

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive functions
7.2 Basic functions
Function Manual
202 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Overview of important parameters (see SINAMICS S110 List Manual)
p0145 Activate/deactivate encoder interface
r0146 Encoder interface active/inactive
p0895 BI: Activate/deactivate power unit component
r0896.0 BO: Parking axis status word
p0897 BI: Parking axis selection
7.2.8 Runtime (operating hours counter)
Total system runtime
The total system runtime is displayed in p2114 (Control Unit). Index 0 indicates the system
runtime in milliseconds after reaching 86.400.000 ms (24 hours), the value is reset. Index 1
indicates the system runtime in days.
At power-off the counter value is saved.
After the drive unit is powered-up, the counter continues to run with the value that was saved
the last time that the drive unit was powered-down.
Relative system runtime
The relative system runtime after the last POWER ON is displayed in p0969 (Control Unit).
The value is in milliseconds and the counter overflows after 49 days.
Actual motor operating hours
The motor operating hours counter p0650 (drive) is started when the pulses are enabled.
When the pulse enable is withdrawn, the counter is stopped and the value saved.
If p0651 is at 0, the counter is de-activated.
If the maintenance interval set in p0651 is reached, fault F01590 is triggered. Once the
motor has been maintained, the maintenance interval must be reset.
CAUTION
If the motor data set is switched during the star/delta switchover without the motor being
changed, the two values in p0650 must be added to determine the correct number of motor
operating hours.
Operating hours counter for the fan
The operating hours of the fan in the power unit are displayed in p0251 (drive).
The number of hours operated can only be reset to 0 in this parameter (e.g. after a fan has
been replaced). The service life of the fan is entered in p0252 (drive). Alarm A30042 is
output 500 hours before this figure is reached. Monitoring is deactivated when p0252 = 0.