Diagnostics
5.3 Fault and alarm messages
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
105
5.3 Fault and alarm messages
5.3.1 General information about faults and alarms
Description
The errors and states detected by the individual components of the drive system are
indicated by messages.
The messages are categorized into faults and alarms.
Note
The individual faults and alarms are described in the SINAMICS S110 List Manual in the
section titled "Faults and Alarms". Here you can also find a chapter titled "Function
diagrams" → "Faults and alarms", which contains function diagrams for the fault buffer, alarm
buffer, fault trigger, and fault configuration.
Properties of faults and alarms
Faults
Are identified by Fxxxxx.
Can lead to a fault reaction.
Must be acknowledged once the cause has been remedied.
Status via Control Unit and LED RDY.
Status via PROFIBUS status signal ZSW1.3 (fault active).
Entry in the fault buffer.
Alarms
Are identified by Axxxxx.
Have no further effect on the drive.
The alarms are automatically reset once the cause has been remedied. No
acknowledgment is required.
Status via PROFIBUS status signal ZSW1.7 (alarm active).
Entry in the alarm buffer.