Drive functions
7.3 Function modules
Function Manual
258 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Overview of important parameters (see SINAMICS S110 List Manual)
p2616 EPOS traversing block, block number
p2617 EPOS traversing block, position
p2618 EPOS traversing block, velocity
p2619 EPOS traversing block, acceleration override
p2620 EPOS traversing block, deceleration override
p2621 EPOS traversing block, task
p2622 EPOS traversing block, task parameter
p2623 EPOS traversing block, task mode
p2625...p2630 BI: EPOS block selection bits 0 ... 5
7.3.6.6 Travel to fixed stop
Description
The "Travel to fixed stop" function can be used, for example, to traverse sleeves to a fixed
stop against the workpiece with a predefined torque. In this way, the workpiece can be
securely clamped. The clamping torque can be parameterized in the traversing task (p2622).
An adjustable monitoring window for travek to fixed stop prevents the drive from traveling
beyond the window if the fixed stop should break away.
In positioning mode, travel to fixed stop is started when a traversing block is processed with
the FIXED STOP command. In this traversing block, in addition to the specification of the
dynamic parameterized position, speed, acceleration override and deceleration override, the
required clamping torque can be specified as task parameter p2622. From the start position
onwards, the target position is approached with the parameterized speed. The fixed stop (the
workpiece) must be between the start position and the braking point of the axis; that is, the
target position is placed inside the workpiece. The preset torque limit is effective from the
start, i.e. travel to fixed stop also occurs with a reduced torque. The preset acceleration and
deceleration overrides and the current speed override are also effective. Dynamic following
error monitoring (p2546) in the position controller is not effective when traveling to the fixed
stop. As long as the drive travels to the fixed stop or is in fixed stop, the "Travel to fixed stop
active" status bit r2683.14 is active.

Table of Contents

Other manuals for Siemens SINAMICS S110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S110 and is the answer not in the manual?

Siemens SINAMICS S110 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S110
CategoryMedia Converter
LanguageEnglish

Related product manuals