Communication
9.2 Communication according to PROFIdrive
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
523
9.2.2 Application classes
Description
There are different application classes for PROFIdrive, depending on the scope and type of
the application processes. There are a total of 6 application classes in PROFIdrive, of which
4 are discussed here.
Application class 1 (standard drive)
In the most basic case, the drive is controlled via a speed setpoint by means of PROFIBUS.
In this case, speed control is fully handled in the drive controller. Typical application
examples are basic frequency converters. Pump and fan control.
6SHHGVHWSRLQW 6SHHGDFWXDOYDOXH
2SHQ/RRS6SHHG&RQWURO
&ORVHG/RRS6SHHG&RQWURO
2SHQ/RRS6SHHG&RQWURO
&ORVHG/RRS6SHHG&RQWURO
2SHQ/RRS6SHHG&RQWURO
&ORVHG/RRS6SHHG&RQWURO
'ULYH
'ULYH 'ULYH
(QFRGHU
RSWLRQDO
(QFRGHU
RSWLRQDO
(QFRGHU
RSWLRQDO
7HFKQRORJ\
$XWRPDWLRQ
352),%86352),1(7
M MM
Figure 9-2 Application class 1