Parameterization using the Basic Operator Panel 20
6.2 Displays and using the BOP20
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
117
BOP20 functions
Table 6- 3 Functions
Name Description
Units The units are not displayed on the BOP.
Access level The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected using the BOP.
Unplug while voltage is
present
The BOP can be withdrawn and inserted under voltage.
The ON and OFF keys have a function.
When withdrawing, the drive is stopped.
Once the BOP has been inserted, the drive must be switched on again.
.
ON and OFF keys have no function
Withdrawing and inserting has no effect on the drive.
Actuating keys The following applies to the "P" and "FN" keys:
When used in a combination with another key, "P" or "FN" must be pressed first and then
the other key.
Parameters for BOP
Drive object, Control Unit
p0003 BOP access level
p0009 Device commissioning, parameter filter
r0019 CO/BO: Control word, BOP
p0977 Save all parameters
SERVO drive object
p0010 Commissioning parameter filter
6.2 Displays and using the BOP20
Features
Operating display
Changing the active drive object
Displaying/changing parameters
Displaying/acknowledging faults and alarms
Controlling the drive using the BOP20