Diagnostics
5.3 Fault and alarm messages
Function Manual
114 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
ZSW2: Valid for SIMODRIVE 611 Interface Mode p2038=1 (function diagram 2453)
Bit 11 - 12 Alarm classes alarms
= 0: Alarm (former alarm level)
= 1: Alarm class W_NCA alarms
= 2: Alarm class W_NCB alarms
= 3: Alarm class W_NCC alarms
These attributes for differentiating the alarms are assigned implicitly to the appropriate alarm
numbers. The reaction to the existing alarm classes in the alarm is defined by the user
program in the higher-level control.
Explanations of the alarm classes
W_NCA: Drive operation currently not limited
e.g. alarm when measurement systems inactive
no limitation on current movement
Prevent possible switching to the defective measuring system
W_NCB: Time-limited operation
e.g. prewarning temperature: without further action the drive may need to be switched
off
after a timer stage → additional fault
after exceeding a trip threshold → additional fault
W_NCC: Functionally limited operation
e.g. reduced voltage/current/torque/speed limits (i2t)
e.g. continue with reduced accuracy / resolution
e.g. continue without encoder