Drive functions
7.1 Servo control
Function Manual
130 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
%DFN
ZDUGV
PRWRUL]HG
)RU
ZDUGV
PRWRUL]HG
)RUZDUGV
UHJHQHUD
WLYH
%DFNZDUGV
UHJHQHUD
WLYH
7KHTXDGUDQWV
7RUTXHIDFWRU0LT
LTBVHWB
6HWSRLQWIRUWRUTXHJHQHUDWLQJFXUUHQW
(IIHFWLYHWRUTXHOLPLWV>1P@
LTOLPLWDWLRQFXWVILOWHURYHUVKRRWV
U
U

Q
0

ದ

ದ
LTBVROOB
U
>@
>@
>@
>@
\
[
>$@
Figure 7-8 Current/torque setpoint limiting
Note
This function is effective immediately without any settings. The user can also define further
settings for limiting the torque.
Properties
The connector inputs of the function are initialized with fixed torque limits. If required, the
torque limits can also be defined dynamically (during operation).
A control bit can be used to select the torque limitation mode. The following alternatives
are available:
Upper and lower torque limit
Motor and regenerative torque limit
Additional power limitation configurable
Motor mode power limit
Regenerative mode power limit
The following factors are monitored by the current controller and therefore always apply
in addition to torque limitation:
Stall power
Maximum torque-generating current
Offset of the setting values also possible (see "Example: Torque limits with or without
offset").
The following torque limits are displayed via parameters:
Lowest of all upper torque limits with and without offset
Highest of all lower torque limits with and without offset