EasyManua.ls Logo

Siemens SINAMICS S110 - Page 167

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive functions
7.1 Servo control
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
165
Note
When fault F07414 occurs, p1990 is automatically started; if p1980 is not equal to 99 and
p0301 does not refer to a catalog motor with an encoder that is adjusted in the factory.
Overview of important parameters (see SINAMICS S110 List Manual)
p0325[0...n] Motor pole position identification current 1st phase
p0329[0...n] Motor pole position identification current
p0404.15 Commutation with zero mark
p0431 Angular commutation offset
p1980[0...n] Pole position identification procedure
p1981[0...n] Pole position identification maximum movement
p1982[0...n] Pole position identification selection
p1983 Pole position identification test
r1984 Pole position identification angular difference
r1985 Pole position identification saturation curve
r1987 Pole position identification trigger curve
p1990 Pole position identification commutation angle offset commissioning
r1992 Pole position identification diagnostics
p1993 Pole position identification current, motion based
p1994 Pole position identification rise time motion based
p1995 Pole position identification motion based P gain
p1996 Pole position identification motion based integral action time
p1997 Pole position identification motion based smoothing time

Table of Contents

Other manuals for Siemens SINAMICS S110

Related product manuals