Drive functions
7.2 Basic functions
Function Manual
188 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Function in STARTER
To call up the function for converting units in STARTER, choose Drive object → Configuration
→ Units. The reference parameters can be found under Drive object → Configuration →
Reference parameters.
Overview of important parameters (see SINAMICS S110 List Manual)
p0010 Commissioning parameter filter
p0100 Motor Standard IEC/NEMA
p0505 Selecting the system of units
p0595 Selecting technological units
p0596 Reference quantity, technological units
p2000 CO: Reference frequency/speed
p2001 CO: Reference voltage
p2002 CO: Reference current
p2003 CO: Reference torque
r2004 CO: Reference power
p2005 CO: Reference angle
p2007 CO: Reference acceleration