EasyManua.ls Logo

Siemens SINAMICS S110 - Page 231

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive functions
7.3 Function modules
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
229
37
PRGHO
3RVLWLRQVHWSRLQWLQIURQWRI
SUHFRQWUROEDODQFLQJILOWHU
VBGHOWDBPRQLWWRO
>/8@
S
 )ROORZLQJHUURUZLWKLQWROHUDQFH
U
U
)ROORZLQJHUURUG\Q
))ROORZLQJHUURUWRRKLJK
S
VBDFW
S! >@
3RVLWLRQVHWSRLQWDIWHU
SUHFRQWUROEDODQFLQJILOWHU
Figure 7-45 Following error monitoring
Following error monitoring is activated via p2546 (following error tolerance). If the absolute
value of the dynamic following error (r2563) is greater than p2546, fault F07452 is output and
bit r2648.8 is reset.
&DPVZLWFKLQJVLJQDO
U
V
V
&DPVZLWFKLQJVLJQDO
U
&DPVZLWFKLQJSRVLWLRQ
S
&DPVZLWFKLQJSRVLWLRQ
S
Figure 7-46 Cam controllers
The position controller has two cam controllers. If cam position p2547 or p2548 is passed in
the positive direction (p2521 > p2547 or 2548), then cam signals r2683.8 and r2683.9 are
reset.
Function diagrams (see SINAMICS S110 List Manual)
4020 Zero-speed / positioning monitoring
4025 Dynamic following error monitoring, cam controllers