Drive functions
7.3 Function modules
Function Manual
236 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Table 7- 26 The compensation value is switched in as a function of p2604
p2604 Traversing direction Switch in compensation value
positive none 0
negative immediately
positive immediately 1
negative none
0RGXORUDQJH
S


0RGXORFRUUHFWLRQ
DFWLYDWLRQ
S
U
3RVLWLRQVHWSRLQW
GHDFWLYDWHG
Figure 7-48 Modulo offset
A modulo axis has an unrestricted traversing range. The value range of the position repeats
itself after a specific value that can be parameterized (the modulo range or axis cycle), e.g.
after one revolution: 360° → 0°. The modulo range is set in parameter p2576, the offset is
activated with parameter p2577. The modulo offset is undertaken at the setpoint end. This is
provided with the correct sign via connector output r2685 (correction value) to appropriately
correct the position actual value. EPOS initiates the activation of the correction via a rising
edge of binector output r2684.7 (activate correction) (r2685 (correction value) and r2684.7
(activate correction) are already connected as standard with the corresponding
binector/connector input of the position actual value conditioning). Absolute positioning
details (e.g. in a traversing task) must always be within the modulo range. Modulo offset can
be activated for linear and rotary length units. The traversing range cannot be limited by a
software limit switch.
With active modulo offset and the application of absolute encoders, as a result of potential
encoder overflows, it must be ensured that there is an integer ratio v between the multiturn
resolution and the modulo range.
The ratio v can be calculated as follows:
1. Motor encoder without position tracking:
v = p0421 * p2506 * p0433 * p2505 / (p0432 * p2504 * p2576)
2. Motor encoder with position tracking for the load gear:
v = p2721 * p2506 * p0433 / (p0432 * p2576)
3. Motor encoder with position tracking for the load gear:
v = p2721 * p2506 / p2576
4. Direct encoder without position tracking:
v = p0421 * p2506 * p0433 / (p0432 * p2576)
With position tracking it is recommended to change p2721.