FIXED STOP
The FIXED STOP task triggers a traversing movement with reduced torque to fixed stop.
The following parameters are relevant:
p2616[x] Block number
p2617[x] Position
p2618[x] Velocity
p2619[x] Acceleration override
p2620[x] Acceleration override
p2623[x] Task mode
p2622[x] Clamping torque [0.01 Nm] task parameter for rotary motors.
Possible continuation conditions include END, CONTINUE_WITH_STOP,
CONTINUE_EXTERNAL, CONTINUE_EXTERNAL_WAIT.
ENDLESS POS, ENDLESS NEG
Using these tasks, the axis is accelerated to the specified velocity and is moved, until:
A software limit switch is reached.
A STOP cam signal has been issued.
The traversing range limit is reached.
Motion is interrupted by the control signal "no intermediate stop/intermediate stop
(p2640).
Motion is interrupted by the control signal "do not reject traversing task/reject traversing
task" (p2641).
An external block change is triggered (with the appropriate continuation condition).
The following parameters are relevant:
p2616[x] Block number
p2618[x] Velocity
p2619[x] Acceleration override
p2623[x] Task mode
All continuation conditions are possible.