Drive functions
7.3 Function modules
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
277
Properties for automatic mode (p1041 = "1")
The input setpoint is specified via a connector input (p1042).
The motorized potentiometer acts like a "normal" ramp-function generator.
Configurable ramp-function generator, e.g.:
Switch on/off (p1030.1)
Ramp-up/ramp-down time (p1047/p1048)
Setting value (p1043/p1044)
Initial rounding active/not active (p1030.2)
Non-volatile storage of the setpoints via p1030.3
Configurable setpoint for Power ON (p1030.0)
Starting value is the value in p1040 (p1030.0 = 0)
Starting value is the stored value (p1030.0 = 1)
Function diagrams (see SINAMICS S110 List Manual)
1550 Setpoint channel
2501 Control word sequence control
3020 Motorized potentiometer
Overview of important parameters (see SINAMICS S110 List Manual)
p1030[D] Motorized potentiometer, configuration
p1035[C] BI: Motorized potentiometer, setpoint, raise
p1036[C] BI: Motorized potentiometer, setpoint, lower
p1037[D] Motorized potentiometer, maximum speed
p1038[D] Motorized potentiometer, minimum speed
p1039[C] BI: Motorized potentiometer, inversion
p1040[D] Motorized potentiometer, starting value
p1041[C] BI: Motorized potentiometer, manual/automatic
p1042[C] CI: Motorized potentiometer, automatic setpoint
p1043[C] BI: Motorized potentiometer, accept setpoint
p1044[C] CI: Motorized potentiometer, setting value
r1045 CO: Motorized potentiometer, speed setpoint in front of the ramp-function
generator
p1047[D] Motorized potentiometer, ramp-up time
p1048[D] Motorized potentiometer, ramp-down time
r1050 CO: Motorized potentiometer, setpoint after the ramp-function generator
p1082[D] Maximum speed