Loading...
Drive functions
7.3 Function modules
Function Manual
286 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Function diagrams (see SINAMICS S110 List Manual)
1550 Setpoint channel
3060 Basic ramp-function generator
3070 Extended ramp-function generator
3080 Ramp-function generator selection, status word, tracking
Signal overview (see SINAMICS S110 List Manual)
Control signal STW1.2 OFF3
Control signal STW1.4 Enable ramp-function generator
Control signal STW1.5 Start/stop ramp-function generator
Control signal STW1.6 Enable setpoint
Control signal STW2.1 Bypass ramp-function generator
Parameterization with STARTER
The "ramp-function generator" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool:
Figure 7-67 STARTER icon for "ramp-function generator"
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
p1115 Ramp-function generator selection
p1120[D] Ramp-function generator ramp-up time
p1121[D] Ramp-function generator ramp-down time
p1122[C] BI: Bypass ramp-function generator
p1130[D] Ramp-function generator initial rounding time
p1131[D] Ramp-function generator final rounding time
p1134[D] Ramp-function generator rounding type
p1135[D] OFF3 ramp-down time
p1136[D] OFF3 initial rounding time
p1137[D] OFF3 final rounding time
p1140[C] BI: Enable ramp-function generator
p1141[C] BI: Start ramp-function generator
p1143[C] BI: Ramp-function generator, accept setting value

Table of Contents