Safety Integrated Functions
8.1 Standards and regulations
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
327
67$57
'HWHUPLQLQJWKHPDFKLQHOLPLWV
,GHQWLI\LQJWKHSRWHQWLDOKD]DUG
5LVNDVVHVVPHQW
5LVNHYDOXDWLRQ
5LVNUHGXFWLRQ
,VWKHPDFKLQHVDIH"
1R
<HV
(1'
5LVNDQDO\VLV 5LVNDVVHVVPHQW
0LQLPL]LQJULVNVDQGVHOHFWLQJVXLWDEOHSURWHFWLYHPHDVXUHVDUHQRWSDUWRIWKHULVNDVVHVVPHQW
Figure 8-2 Iterative process to achieve the required level of safety to ISO 14121-1
Risks must be reduced by designing and implementing the machine accordingly (e.g. by
means of controllers or protective measures suitable for the safety-related functions).
If the protective measures involve the use of interlocking or control functions, these must be
designed in accordance with EN ISO 13849-1. For electrical and electronic controls, EN
62061 can be used as an alternative to EN ISO 13849-1. Electronic controls and bus
systems must also comply with IEC/EN 61508.