EasyManua.ls Logo

Siemens SINAMICS S110 - Page 365

Siemens SINAMICS S110
714 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety Integrated Functions
8.5 Safety Integrated Extended Functions
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
363
Restrictions for Safety Integrated Extended Functions "without encoder"
The following restrictions apply for the Safety Extended Functions "without encoder":
Only operation with motors of type
1 SIEMOSYN
No operation for units with the following design
1 Blocksize GX
2 Chassis
Technological restrictions
1 Pulling loads are not permitted
2 The slip of an induction motor must be taken into account
No operation in conjunction with the following functions
1)
1 Flying restart
2 Current limitation I
lim
3 DC brake
4 Compound brake
5 SW pulse logic
6 Motor identification
7 Motor data set changeover of synchronous and induction motors is not permitted
8 Pulse pattern technique for encoderless vector control of synchronous motors (selected
using p1750.5)
1)
Note: Activation of a Safety motion monitoring function and simultaneously using these drive
functions results in a Safety fault.
Performance restrictions
1 Within1 s only one start-up and one down-ramp are permitted
2)
2 The permissible ramp time is a minimum of 1 second for synchronous motors (the ramp
time depends on the power rating)
3 Current controller cycle of 32.5 µs result in a fault in the Motor Module
3)
2)
Note: For a cycle "0 → +n
set
→ -n
set
→ 0, a minimum period of 2 s is required.
2)
Note: This means that a current controller cycle of 62.5 µs on a double-axis Motor Module with 2
Safety axes is also not possible.

Table of Contents