Safety Integrated Functions
8.6 Controlling the safety functions
Function Manual
424 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
PROFIsafe status word (ZSW)
S_ZSW1, PZD1 in telegram 30, input signals
See function diagram [2840].
Table 8- 17 Description of the PROFIsafe status word (ZSW)
Bit Meaning Remarks
1 STO active 0 STO active
0 STO not active
1 SS1 active 1 SS1 active
0 SS1 not active
2 SS2 active 0
1
3 SOS active 0
1
4 SLS active 0
1
5 Reserved -
6 Reserved -
1 Internal event 7 Internal Event
0 No internal event
8 Reserved -
9 Active SLS level bit 0 -
10 Active SLS level bit 1 -
1
11 SOS selected 0
1
12...14 Reserved -
15 SSM (speed) 0
1
1
Signals not relevant to Basic Functions should be set to "0".