Safety Integrated Functions
8.7 Commissioning
Function Manual
442 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Test stop mode 1
$FWXDWRU
9H[W
0
'2
'2
&8
',$*
'2
'2
Figure 8-26 F-DO circuit, test stop mode 1
Test step
1)
DO+ DO- DIAG signal expectation
0 ... 3 Synchronization
4 OFF OFF LOW
6 ON ON LOW
8 OFF ON LOW
10 ON OFF HIGH
12 OFF OFF LOW
Test sequence for test stop mode 1
1)
You can find a complete list of the steps in the SINAMICS S110 List Manual under message F01773.