Commissioning with PROFIBUS
3.2 STARTER commissioning tool
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
49
2. Use STARTER to download project to PG:
– Connect with target system (go online)
– Downloading the project into the PG
3. Install the latest firmware version for the project.
– In the project navigator, right-click Drive unit → Target device → Device version.
– For example, select version "SINAMICS S110 V4.3x" -> Change version.
Update the firmware and load the new project to the target device.
1. Insert the memory card containing the new firmware version into the Control Unit:
– Disconnect the Control Unit from the power supply →
– Insert the memory card containing the new firmware version →
– Power up the Control Unit again.
2. Go online and download the project to the target device → Copy RAM to ROM.
3. Upgrading the firmware for the DRIVE-CLiQ components takes place automatically.
4. Reset the drive unit using a POWER ON (Control Unit and all DRIVE-CLiQ components).
The new firmware version is only effective in the DRIVE-CLiQ components from this point
onwards; it also appears in the version overview.