Communication
9.4 Communication via PROFINET IO
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
631
Configuring
Configuring the three versions is only briefly sketched out in the following:
Compact module:
Insert a module "DO Servo/Servo/...".
Assign the I/O addresses.
Subslot configuring without new functionality:
Insert a module "DO with telegram xyz".
Insert a submodule "PZD telegram xyz".
Assign the I/O addresses.
Subslot configuring with optional PROFIsafe and PZD extension:
Insert a module "DO Servo/Servo/...".
Insert the optional submodule "PROFIsafe telegram 30".
Insert a submodule "PZD telegram xyz".
Insert the optional submodule "PZD extension".
Assign the I/O addresses for the module and the submodules.
You will find a detailed description for processing a GSD file in HW Config in the SIMATIC
documentation.