EasyManua.ls Logo

Siemens SITRANS TSinsert - Page 37

Siemens SITRANS TSinsert
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WARNING
Connecting or disconnecting device in energized state
Risk of explosion in hazardous areas.
Connect or disconnect devices in hazardous areas only in a de-energized state.
Exceptions:
Devices having the type of protection "Intrinsic safety Ex i" may also be connected in
energized state in hazardous areas.
Note
Electromagnetic compatibility (EMC)
You can use this device in industrial environments, households and small businesses.
For metal enclosures there is an increased electromagnetic compatibility compared to high-
frequency radiation. This protection can be increased by grounding the enclosure.
See also
Connecting (Page 35)
Note
Improvement of interference immunity
Lay signal cables separate from cables with voltages > 60 V.
Use cables with twisted wires.
Keep device and cables at a distance from strong electromagnetic 󹪝elds.
Take account of the conditions for communication speci󹪝ed in the Technical data (Page 127).
Use shielded cables to guarantee the full speci󹪝cation according to HART/PA/FF/Modbus/
EIA-485/Pro󹪝bus DP.
Connecting
5.1 Basic safety notes
SITRANS TS100/TS200/TS300/TS500/TSinsert/TSthermowell
Operating Instructions, 08/2020, A5E47810090-AA 37

Table of Contents

Other manuals for Siemens SITRANS TSinsert

Related product manuals