GoodWe
1. In the inverter insert the RJ45 plug into the "RS-485 out" socket.
2. Insert the terminal block connector into the Solar-Log™ RS485/422 B or C socket.
Connect the inverters to each other
Connect using a network cable (patch cable).
Where to connect: RJ45 socket on the outside of the inverter.
Procedure
1. Insert the RJ45 plug in inverter 1 into the RJ45 socket.
2. Insert the other end of the wire into the other RJ45 socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Insert the terminal block connector into the Solar-Log™ RS485/422 B or C socket.
5. Terminate the last inverter according to the inverter instructions.