Platinum (formerly Diehl Ako)
61.2 PlatinumH
Termination Addressing Interface
Yes Yes RS485
Select “Platinum: H-Serie” during the inverter detection
Overview
Integrated interface
Where to connect: Terminal strip inside the inverter
2-pin wiring
Communication address must be allocated
Installation steps
Switch off the inverters and Solar-Log™
Connect inverters to the Solar-Log™
Connect the inverters to each other
Configure the inverter’s communication interface
Allocate communication address
Connect inverters to the Solar-Log™
The wiring is done using a
self-made, shielded 2 wire data cable and terminal block connector.
Procedure
1. Connect wires as shown in the diagram below.
Solar-Log™ terminal strip connector Inverter terminal strip
Terminal Terminal
1 B (Data +)
4 A (Data -)
2. If no further inverter is connected, terminate the inverter according to the instructions for the inverter.
3. Close the inverter cover if no other inverters are to be connected.
4. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
The inverters are connected together using
the RS485 interface. Refer to the manufacturer’s inverter manual for the details on how to setup the connection.
Allocate communication address
Recommendation: Continuous numbering starting with 1
Setting: Using the inverter operating display
Procedure: Start according to the inverter’s instructions