Rishabh Instruments Pvt. Ltd.
72RishabhInstrumentsPvt.Ltd.
72.1 Rishabh-Radius
Termination Addressing Interface
- Yes RS485
Selections available under Rishabh; Type: „Radius“; Interface: „RS485“
Supported models (as of firmware 4.2.0):
•
10KwAE 1mppt
•
10KwAE 2mppt
•
12KwAE 1mppt
•
12KwAE 2mppt
•
15KwAE 2mppt
•
18KwAE 2mppt
•
20KwAE 2mppt
•
20KwAE 3mppt
•
10KwEE 1mppt
•
15KwEE 1mppt
•
20KwEE 1mppt
Overview
•
Integrated interface.
•
Where to connect: Terminal strip inside the inverter.
•
2-pin wiring.
•
The communication address has to be assigned.
•
Installation steps:
• Switch off the inverters and the Solar-Log™.
• Connect the inverters to the Solar-Log™.
• Assign the communication address.
• Terminate inverter.
Connect the inverters to the Solar-Log™
The wiring is done using a:
•
self-made, shielded 2-wire data cable and terminal block connector.
Note
Rishabh have two RS485 connections (A and B). Due to the required baud rate of 38400, Solar-Log™
only supports the RS485 A connection.