Polycab
62 Polycab
62.1 Polycab
Termination Addressing Interface
Yes Yes RS485
Supported models (as of firmware 4.1.1):
PSIS series:
0.7K, 1K, 1.5K, 2.0K, 2.5K, 3K, 3.6K, 4K, 4.6K, 5K, 3K-ST, 3.6K-ST
PSIT series:
6K, 10K, 15K, 20K, 25K, 30K, 36K, 40K, 50K-DC
Overview
Integrated interface
Where to connect: Between the COM round sockets on the outside of the inverter
2-pin wiring
Communication address must be allocated
Installation steps
Switch off the inverters and Solar-Log™
Connect inverters to the Solar-Log™
Connect the inverters to each other
Allocate communication address
Note!
It is important to note that there are two different wiring types for the Polycab model.
Refer to the wiring table further below.
Connect inverters to the Solar-Log™
The wiring is done using a
ready-made data cable (supplied with the inverter).
or
self-made, shielded 2 wire data cable with round plug and terminal block connector.