ABB
4.6 ABB-SunspecviaEthernet
Termination Addressing Interface
No Yes LAN
Selections available under ABB; Type: „Sunspec“; Interface: „Ethernet.“
Supported models (as of firmware 4.1.2):
TRIO-50.0-TL-OUTD, TRIO-50.0-TL-OUTD-US-480
TRIO-TM-50.0-400
TRIO-TM-60.0-480, TRIO-TM-60.0-480-US
Overview
Integrated interface.
The IP address for the inverter has to be either assigned via DHCP or a static IP has to be assigned.
Connected using network cable (patch cable) and Ethernet router.
Installation steps:
Turn the Solar-Log™ off.
Turn the inverters off.
Connect inverters to the router.
Connect the Solar-Log™ to the router.
Connect the inverters to the Solar-Log™
The wiring is done using a network cable (patch cable/crossover cable) and the Ethernet router.
Connect the inverters to each other
The inverters are connected together using the RJ45 interface and, if needed, a router.
Follow the connection setup according to the inverter‘s instructions.
Assigning IP addresses
In addition to a static, fixed IP, a dynamic IP address can also be assigned.
Please select an IP address with the same class C subnet as the Solar-Log™.
Example: The Solar-Log™ has the IP address 192.168.178.49.
The inverter in this case has to have a free IP address in the same range (from 192.168.178.1 to
192.168.178.254).
Procedure: Start according to the inverter‘s instructions.
*Dynamic IP address (DHCP) for detection and communication:
The Solar-Log™, inverter and router have to be set to obtain their IP addresses automatically (DHCP) and be in the
same class C subnet.