38
ABB
Note
The setting „ModTCP Server“ has to be activated in the inverter in order to be able to communicate
with Sunspec-Ethernet. This setting cannot be adjusted via the inverter‘s display. The inverter has to be
adjusted via a device with a wireless function. More information below under „Setting up the Inverter.“
Setting up the Inverter:
A device with a wireless function such as a laptop, tablet or smartphone is required to set up and configure the
inverter.
The following steps are necessary:
Connect the inverter to a power outlet.
Activate the wireless function of the device used.
Connect the device to the inverter‘s access point (a network with the name ABB-XX-XX-XX-XX-XX-XX appears in
the last, the Xs are the hexadecimal number of the MAC address (the MAC address is printed on the wireless
identification label on the side of the inverter).
Enter „ABBSOLAR“ as the password for the inverter‘s access point.
Open the internet browser and enter the IP address to access the configuration wizard menu: 192.168.117.1
(default address that is always active).
The configuration wizard starts.
Refer to the inverter‘s installation manual for the next steps.
Note
Please also note the instructions the inverter‘s installation manual of the inverter for the set up and
configuration!
Detection via the Solar-Log™ WEB Interface
For detection on the Solar-Log™, select the device class under the menu Configuration | Device | Definition
| Interface
with the plus symbol and then select ABB as the manufacturer, Sunspec as the type and the inter-
face. Confirm your selection with
OK.
Save your selections and then start the Device Detection under Configuration | Device | Detection and start
the device detection.
Detection from the Solar-Log 1200
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings Start
Initial Configuration SPage 2 „Devices“ ADD and select „Inverter,“ „ABB-Sunspec“ and the interface
„Ethernet.“ Save and start the Device Detection.