VARTA Battery System
6 VARTABatterySystem
6.1 VARTAHouse
Termination Addressing Interface
No Yes* LAN
Select „VARTA“ during the device detection (for firmware 3.x and up to 4.2.0).
Select „VARTA:House“ during the device detection (Firmware 4.2.1 and higher).
Compatible Battery systems
VARTA home
VARTA family
VARTA element
VARTA pulse
Overview
Integrated interface.
Connected using network cable (patch cable) and Ethernet router or switch (when assigning a static IP ad-
dress).
*The Varta battery system is set to DHCP by default. However, it can also be assigned a static IP address.
(Refer to the manufacturer‘s manual).
Installation steps:
Assign a dynamic or a static IP address.
Switch off the battery system and Solar-Log™.
Connect the battery system to the Solar-Log™.
Connect the inverters to the Solar-Log™ according to the inverter instructions.
Connect the consumption meter to the Solar-Log™ according to the instructions.
Assign the inverter‘s communication address according to the inverter instructions (if required).
Note:
The following components have to be used for battery monitoring to work:
Battery system with net energy meter (at least Varta firmware 3.0.2).
Inverters.
Consumption meter.
The consumption meter is to be installed so that it not records the battery charge. In addition, the
"Consumption meter includes battery charge" settings has to be deactivated in the
Configuration
| Devices | Configuration | Battery menu
via the WEB interface.