192
Kostal and Solar-Fabrik
1. Insert the RJ45 plug into any RJ45 socket on the first inverter.
2. If no further inverter connected, terminate the inverter:
On the inverter insert the connection plug into the free RJ45 socket.
3. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
•
Connect using the RS485 data cable with RJ45 plug;
Connection cables between the inverters are supplied with the inverters. Use these.
•
Where to connect: RJ45 socket on the outside of the inverter
Procedure
1. Insert the RJ45 plug into the free RJ45 socket on the first inverter.
2. Insert the other end of the wire into any RJ45 socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter.
Insert the connection plug into the free RJ45 socket.
Allocate communication address
1. Recommendation: Continuous numbering starting with 1 (address range 1-99).
2. Setting: via display of the inverter.
3. Procedure: Start according to the inverter‘s instructions