239
Q3
Note
Each inverter has to be individually reachable via the network. For this, the network interface has to be
activated for every inverter (select "Activate LAN" under the LAN menu) and and the inverter needs to
be connected to the local access network (LAN) via a switch.
Detection via the Solar-Log™ WEB Interface
For detection on the Solar-Log™ , select the device class under the menu Configuration | Device | Definition |
Interface with the plus symbol and then select “Q3:QX3“ as the manufacturer. Confirm your selection with OK.
Save your selections and then start the Device Detection under Configuration | Device | Detection.
Detection from the Solar-Log 1200
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings ►Start
Initial Configuration Page 2 „Device“ Add and select the manufacturer “Q3:QX3“ from there. Save and
start the Device Detection.
Note for feed-in management
Supported by Solar-Log
starting with inverter firmware version 19
Note
Using the inverter's web interface, select "External control via network interface" under “Settings
Installation Grid Company Settings Power Reduction," and under “cos(phi) Settings.”