292
SiNeng
Connect the inverters to each other
•
Where to connect: Terminal block inside the inverter.
•
Connect the inverters to each other according to the inverter instructions.
Assign the communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Via operating display (on the inverter) or via APP or via a software tool (please follow the inverter
instructions).
•
Procedure: Start according to the inverter‘s instructions.
Detection via the Solar-Log™ WEB Interface
•
For detection on the Solar-Log™, select the device class under the menu Configuration | Device | Definition
| Interface
with the plus symbol and then select SiNeng as the manufacturer, SP as the type and the interfa-
ce. Confirm your selection with
OK.
•
Save your selections and then start the Device Detection under Configuration | Device | Detection and start
the device detection.
Detection from the Solar-Log 1200
•
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings ► Start
► Initial Configuration ► Page 2 „Devices“ ► ADD and select „Inverter,“ „SiNeng“ and the interface „RS485.“
Save and start the Device Detection.
Note
A maximum of 32 inverters can be connected per RS485 bus.