EasyManua.ls Logo

Solare Datensysteme Solar-Log - Page 292

Solare Datensysteme Solar-Log
506 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
292
SiNeng
Connect the inverters to each other
Where to connect: Terminal block inside the inverter.
Connect the inverters to each other according to the inverter instructions.
Assign the communication address
Recommendation: Continuous numbering starting with 1.
Setting: Via operating display (on the inverter) or via APP or via a software tool (please follow the inverter
instructions).
Procedure: Start according to the inverter‘s instructions.
Detection via the Solar-Log™ WEB Interface
For detection on the Solar-Log™, select the device class under the menu Configuration | Device | Definition
| Interface
with the plus symbol and then select SiNeng as the manufacturer, SP as the type and the interfa-
ce. Confirm your selection with
OK.
Save your selections and then start the Device Detection under Configuration | Device | Detection and start
the device detection.
Detection from the Solar-Log 1200
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings Start
Initial Configuration Page 2 „Devices“ ADD and select „Inverter,“ „SiNeng“ and the interface „RS485.“
Save and start the Device Detection.
Note
A maximum of 32 inverters can be connected per RS485 bus.

Table of Contents