324
SolarMax
1. Insert the RJ45 plug into any RJ45 socket on inverter 1.
2. Close the inverter if no other inverters are to be connected.
3. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
•
Connect using a network cable (patch cable)
•
Where to connect: RJ45 socket inside the inverter (on the retrofitted RS485 interface)
Procedure
1. Open the inverter as shown in the inverter‘s instructions.
2. Insert the RJ45 plug into any RJ45 socket on inverter 1.
3. Insert the other end of the wire into any RJ45 socket on inverter 2.
4. Connect the other inverters to each other in the same way.
5. Close inverters.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Using the inverter operating display
•
Procedure: Start according to the inverter‘s instructions
Note for feed-in management
The inverter itself has to be configured with MaxTalk2 (SolarMax's software) and set to "Remote mode"
to be able to use reactive power management. Please refer to the inverter instructions for more infor-
mation on this topic.