Solectria
Procedure
1. Open the inverter according to the inverter‘s instructions.
2. Connect the other inverters to each other in the same way.
3. Terminate the last inverter according to the inverter instructions.
4. Close the inverter.
5. Set the communication address via the display according to the inverter‘s instructions. Recommendation:
Continuous numbering starting with 1. Address range 1 - 254.
Note
Check the baud rate for the inverter. The baud rate has to be set to 19200 with stop bits and without
parity (19200-8N1). Follow the manufacturer’s instructions for setting the baud rate.