Conergy
Connect the inverters to the Solar-Log 1000, 1900 and 2000.
Connection is only done using a ready-made data cable, specially for connecting to the Solar-Log 1000 and 2000
(optional extra; not supplied).
Procedure
1. Insert the CAN plug into the inverter CAN IN socket.
2. If no further inverter connected, terminate the inverter:
Insert the two 5 pin 120 terminal resistors from the ready-made cable set into the CAN OUT socket.
3. Insert the terminal block connector into the Solar-Log 1000, 1900 and 2000 CAN socket.
Connecting inverters to each other (only Solar-Log 1000, 1900 and 2000)
Connection is made only with a ready-made data cable specially for connecting the inverters to each other
(optional extra: not supplied).
Where to connect: CAN socket outside the inverter.
Procedure
1. Insert the CAN plug into any CAN OUT socket on inverter 1.
2. Insert the other end of the wire into any CAN IN socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter.
Insert the two 5 pin 120 terminal resistors from the ready-made cable set into the CAN OUT socket.