Chapter 4 - Installation
4.2.2. PNEUMATIC NETWORK
For the arm, and if solenoid valves are used, it is necessary to provide a supply of compressed air, lubricated or
not, at a maximum pressure of 7bar and filtered to 10 µm.
4.2.3. WORK ENVIRONMENT
• Working temperature: 5 to 40°C (NF EN 60204-1) with controller cooling via a filtered fan.
• Storage temperature: -25 to 55° C.
• Humidity: 90% maximum without condensation.
• Maximum altitude: 2000 m.
• Vibrations: please consult us.
• Protection index: IP20.
• Clean environmental air: Class 10 000 (Federal Standard 209E).
If these conditions of cleanness and temperature in particular are not complied with, the controller must be
integrated in a closed area in which the necessary conditions can be provided: A cooled industrial frame. If CS8C
is enclosed in a IP54 cabinet, the door of this external chassis has to remain closed during operation.
The heat generated by the controller is 400 W.