OnAir 2000M2 Digital Mixing Console
Date printed: 12.11.03 SW V 4.0 Configuration 12-13
Note: The OnAir 2000M2 is designed to run at a sampling rate of 48 kHz. Due to
this fact, filter parameters are accurate at 48 kHz only. If the console is
synchronized to 44.1 kHz, the actual center and turnover frequencies of the
EQ are lower by 8.125 %; if the clock frequency is 32 kHz, the frequencies
will be lower by approx. 33.3 %.
If the console is synchronized to an external signal, a message box is dis-
played if synchronization is lost; a “Missing External Clock” warning is
added to the error list.
If the console was synchronized to either WORDCLOCK or AES/EBU
and a “no sync” condition is detected, the console automatically selects the
INTERNAL mode; however, the external clock selection in the SYSTEM
SYNC page is not changed. As soon as a valid external clock signal is
available, the console will be re-synchronized.
If synchronization to a video source is lost, only a message box is dis-
played. The sync source remains in VIDEO mode.
If the Clock Sync module is removed, sync source selection changes to
INTERNAL mode, and no other sync source can be selected.
12.2.10 Automation
More information on this subject can be found in chapter 10.