MultiFlow  Configuration of the MultiFlow
Error Message
Meaning
3181 + Path Selection Extended Electr.
3333 + Pump Position Before
The controller variant specified does not support
additive injection.
31437 Currency Resol. B 3
31438 Res. product price 2
The resolution for the product price must be equal
or greater than the resolution for the applied
currency.
31851 Drain Control Yes
3152 + No. of Discharges 2
With manual residue removal only one liquid
product can be specified per receipt.
3181 + Path Selection Extended Electr.
3187 Hose Set UVPSB
For the controller variants specified no bypass
discharge is possible.
3181 + Path Selection Blow Down (UK)
3187 Hose Set UVPSB
3181 + Path Selection Ext.Electron.(BE)
3187 Hose Set UVPSB
3181 + Path Selection Blow Down (UK)
3187 Hose Set UVPS
For the controller variants specified no unmetered
discharge is possible.
3181 + Path Selection Ext.Electron.(BE)
3187 Hose Set UVPS
31672 Multi-IO Node 21
3163 OBC Node 21
The given components need to have different
node numbers.
31672 Multi-IO Node 0
31642 Remote Ctrl Node 0
31672 Multi-IO Node 0
31652 Level Probe Node 0
31672 Multi-IO Node 0
31663 Deadman Sw. Node 0
Illegal SI-Sensor position
3169711 Start Sensorgrp. 1
3169731 Start Sensorgrp. 1
The start positions of the indicated external
sensor interface sensor inputs are overlapping or
invalid.
Invalid Parameter Combination
31692 SI node
6
3161 Global node no. 2
Invalid sensor interface configuration. Sensor
interface may only be controlled by the master
MultiFlow.
No Sensors activated
31691 Use SI 1
External sensor interface control activated without
defining the sensor inputs.
(35.11.)
------------------------------------------
Product name illegal
.1 + Product name
For each product activated a product name must
be allocated in all 3 languages; empty fields (even
for only one of the three languages) are not
permissible.
(35.11.) Heating Oil
------------------------------------------
Product name illegal
.1 + Product Name Heating Oil
(35.11.) Heating Oil------------------------
------------------Range Error.4 +
Delivery Unit ?????
The parameter specified lies outside the range of
values allowed.
(35.11.) Heating Oil
------------------------------------------
Parameter Conflict
.2 + Product Type Liquid Product
.4 + Delivery Unit Pieces
Liquid products may not be sold as numbers of
pieces.
For the product specified the additive injection is
activated; however, the additive number specified
does not relate to an additive.
(35.19.) Heating Oil+
------------------------------------------
Illegal Value
.52 Additive Code 29
(35.19.) Heating Oil+
------------------------------------------
Parameter Conflict
.51 Use Add. Injector Yes
3333 + Pump Position No
For the product specified the additive injection is
activated; however, according to the setting of
parameter 3333 no additive pump is present.
(35.11.) Heating Oil
------------------------------------------
Parameter Conflict
.2 + Product Type Liquid Product
.73 + Product Group Packed Goods
A liquid product must possess a designation that
is compatible for compensation (product group).