MN F09 002 US DOK-383E Issue/Rev. 3.65 (02/24)
MultiFlow Address and contact details
Appendix B. Parameter summary
Display Configuration / Device Settings
Sets internal clock
IMPORTANT:
Date is subject to W & M restrictions!
Display language for menus, alarms and reports
Display language for deliveries and receipts
Display of grand totals
Long-term and shift counters:
• Sum of uncompensated volume in liters (V
0
)
• Sum of compensated volume in liters (V
T
)
•
Sum of masses in kg
•
Sum of measured additive in liters
NOTE: The day / shift counter can be reset with
function key F1.
This parameter should be assigned the device ID
(name-plate, see housing of operating device).
This parameter is used for identifying the measuring
system. The designation is printed on all delivery
notes and reports.
Recommendation:
Use the serial number of the measuring chamber
(name-plate).
Password protection for electronic W & M seal.
Highest security level;
device settings which are not saved on the parameter chip
High security level due to additional checksum;
parameter transfer from the chip card only possible when seal is
broken !
High security level due to additional checksum;
parameter transfer from the chip card only possible when seal is
broken !
Lowest security level; parameters which are not saved on the chip
card