MultiFlow  Configuration of the MultiFlow
Select the "Checksums" menu item (menu 4.7) to display the version
number and the checksums of the calibration-relevant and non
calibration-relevant program chapter. These serve for unique
identification of the software. Also displays the arithmetic checksum of the
overall software and indicates whether it is an EPROM- or Flash version.
No.
Name
Seal
K
Factory
Setting
Meaning
4.8
Sensor monitor
Can only be selected when the connection to the
sensor interface is active.
4.8.1
Activation
M
0 (no)
(De) activates the sensor monitor. Time and (where
available) GPS position are saved. Monitor remains
active until a sensor status change with an activated
alarm message is detected.
4.8.2
Status
D
Display of current monitor status
4.8.3
Printing
D
Printout of the sensor monitor status report
9.5 Logon
9.6 Load Monitor
No.
Name
Seal
K
Factory
Setting
Meaning
5
Logon
D
Entry of the driver code for a change of drivers
(logon).
6
Load Monitor
M
Displays the actual load status and gives the option to
set the warning level for "additive load undercut"
9.7 Flush measuring system
No.
Name
Seal
K
Factory
setting
Meaning
7
Flush measuring
system
F
Start of the flushing process for the measuring system
Flushing of the measuring system is initiated from menu item 7. The
standard value for the flushing process is the flushing product specified
via parameter 3.1.5.8.1 with the flushing volume defined by parameter
3.1.5.8.2. By this means it is ensured that the flushing volume does not
fall below the specified minimum (parameter 3.1.5.8.3).
9.7.1 In OBC mode
Once orders have been transferred from the OBC to the MultiFlow, it is
not possible to access menu item 7 without losing the OBC orders. The
measuring system flushing is carried out in OBC mode via the variant
defined by parameter 3.1.5.8.4. To have a request for system flushing
appear after processing each product, set this parameter to '1'. If