282
Sening® is a registered trademark of FMC Technologies
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Software update
Print and compare delivery note.
Set and print out W&M seal.
15.3 Software update by exchanging the EPROM chip
Check if the system is functioning correctly.
Print out a list of all parameters.
Make a note of the receipt ID (parameter 3.1.9).
Save parameter setting to the chip card (parameter 4.5.2).
Switch off the voltage of MultiFlow and printer.
A1 model: Open round Ex-housing.
Respective instruction (drawing no. 51.351100, 284) ) must be followed
strictly!
A3 model: Open operator terminal, disconnect plug connector.
Take out electronics mounted on aluminium base plate.
The EPROM is located on the back of the base plate.

Table of Contents