Sening
®
is a registered trademark of FMC Technologies
MN F09 002 US DOK-383E Issue/Rev. 3.65 (02/24)
MultiFlow Printing out Reports
Report date
Version
Meter des.
: 05.03.2009 09:37
: 3.54[3.54]DE
: - ? –
------------------------------------------
The seal is OK!
------------------------------------------
The GPS position can only be given if the MultiFlow is operating with a
GPS-compatible EMIS.
11.11 Event report, sensor monitor
•
The event report prints out all sensor events entered in the logbook in
chronological order with a number (xxxx).
•
Enter a reporting period for which you require a logbook printout.
Sample printout of an event report:
GPS: C'5338.550700'N'953.366200'E'''
SIStat: 0000-----2232 ----- 0
SIIndx: 1111-----2222 ----- 7
GPS: C'5338.549600'N'953.367300'E'''
SI:040309-132915 M:ON I:12 S:2
GPS: C'5338.554600'N'953.364200'E'''
SI:040309-133011 M:ON I:20(7-1) S:1(akt)
GPS: C'5338.554600'N'953.364200'E'''
SI:040309-133015 M:ON I:20(7-1) S:0(pas)
GPS: C'5338.554600'N'953.364200'E'''
SI:040309-133019 M:ON I:20(7-1) S:1(akt)
Detection of a sensor interface
event
ON - Online event
OFF- Offline event
Sensor information
n: SI input
x: sensor group
y: index within sensor group
n: 1 .. 20
x: 1 .. 7 (see parameter 3.1.6.9.7)
y: 1 .. chamber number