MN F09 002 US DOK-383E Issue/Rev. 3.65 (02/24)
MultiFlow Address and contact details
Sening® is a registered trademark of FMC Technologies
Display status of electronic W & M seal.
Print status of electronic W & M seal.
Breaks the electronic W & M seal to obtain access to
sealed parameters.
ATTENTION: This function is not available in some
countries
Saves modified W & M information.
IMPORTANT: To be executed in the presence of a
W & M inspector or service person
only!
Procedure for measuring the meter factors at
various flow rates.
Tests the inputs and outputs.
IMPORTANT: The setting of the outputs is subject
to W & M restrictions!
Loop-back test for testing the printer line with a
special printer connector.
Display link status of all CAN Bus devices.
Testing the radio remote control
(version 5.00 and higher)
Testing the EPE2 functions
Testing the external inputs and outputs of the IO
module (8 outputs, 2 inputs).
Checking the statuses of the activated sensor inputs
of the external sensor module.
To test the TMC telegrams. N/A.
Resets the device parameters (restores the
factory settings).
(version 5.02 and higher)
Resets the device parameters