Sening
®
is a registered trademark of FMC Technologies
161
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Configuration of the MultiFlow
Take care that at least one master is defined, otherwise it is not
possible to change the parameters which are subject to the master
code.
9.4 Service Menu
9.4.1
Electronic seal
No.
Name
Seal
K
Factory
Setting
Meaning
4.1
Electronic seal
4.1.1
Display Seal
D
Display status of electronic W & M seal.
4.1.2
Print Seal
D
Print status of electronic W & M seal.
4.1.3
Break Seal
M/
Cal.
Breaks the electronic W & M seal to obtain access to
sealed parameters.
ATTENTION: This function is not available in some
countries
4.1.4
Restore Seal
M/
Cal.
Saves modified W & M information.
IMPORTANT: To be executed in the presence of a
W & M inspector or service person
only!
9.4.2
Calibration
No.
Name
Seal
K
Factory
Setting
Meaning
4.2
Calibration
Cal.
Procedure for measuring the meter factors at
various flow rates.
9.4.3
Diagnosis
No.
Name
Seal
K
Factory
Setting
Meaning
4.3
Diagnosis
4.3.1
In- / Outputs
M/Cal.
Tests the inputs and outputs.
IMPORTANT: The setting of the outputs is subject
to W & M restrictions!
4.3.2
Printer
M
Loop-back test for testing the printer line with a
special printer connector.
4.3.3
Global CAN Bus
M
Display link status of all CAN Bus devices.
4.3.4
Remote control
M
Testing the radio remote control
4.3.5
---
4.3.6
EPE2
M
(version 5.00 and higher)
Testing the EPE2 functions
4.3.7
IO interface
M/Cal.
Testing the external inputs and outputs of the IO
module (8 outputs, 2 inputs).
4.3.8
Sensor interface
M
Checking the statuses of the activated sensor inputs
of the external sensor module.
4.3.9
TMC test
To test the TMC telegrams. N/A.