37
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  General Installation Instructions
If the change of the battery is performed within 5 seconds, the data will
not be erased!
The date must be adjusted before the W & M seal is set, because it is
subject to W & M protection.
3.5.2
Maintenance plan
Daily
Monthly
Yearly
Other
MultiFlow
AI version
-
-
-
x
(safety check according
to IEC/EN 60079-17)
Battery
change
-
-
-
x
(approx. every 7 years)
3.6 Safety instructions
Caution:
This information must be carefully read and observed before operating
the unit.
3.6.1
Ex protection
The measuring systems are designed for flow measurements of
highly flammable and flammable liquids (hazard classes AI and
AIII) on tank trucks. Sparks and naked flames must be strictly
avoided.
3.6.2
Special requirements
The measuring systems contain high-precision, high-quality components.
Consequently, mechanical actions not directly relating to the operation of
the unit (e.g. dropping the unit) must be avoided.
§ The measuring devices must be properly and officially calibrated. Any
manipulation, whether intentional or unintentional, will break the
calibration seal.